Pre-installation Notes
Dual Flush and Variflush are not suitable for concealed cisterns
- Check that the system flushes effectively. Variflush/Dual Flush will save water, but cannot improve a flushing system that is already defective.
- The cistern must have the lever in front.
- The cistern should have a 19 mm ( 3/4 inch) minimum hole for the lever. Note that some plastic cisterns have a small hole that will need enlarging.
- Use Type B for very thin plastic slim line cisterns where the metal rod attached to the lever is supported at the rear of the cistern.
- For Type B a clearance of 50 mm (2 inch) is required inside the cistern.
|
Installation
- Remove existing flush lever, plastic bush and lifting arm.
- Insert threaded bush and secure with nut.
- Locate body onto threaded bush, insert lever and knob assembly. Secure with circlip.
- Fit lifting arm
- Drill a 10 mm ( 3/8 inch) hole in top of siphon.
- Push in rubber bush and connect the tube from the body to the top of the siphon using the two elbows
|
Dual Flush Installation
Contact sales@Peterton.co.uk with questions or comments regarding this site. Copyright 2008 Peterton Ltd. All rights reserved.
|